Jump to Latest Follow 1 - 10 of 10 Posts. A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. Buy Air Conditioner Parts at Lowest Market Price then Shop Here at PartsAPS! Older thermostats either had dials or simple LCD screens that didn’t need much voltage. Southwire Electrical Cable - Copper Electrical Wire Gauge 6/19. Close. By using our Services or clicking I agree, you agree to our use of cookies. $230.35. Any ideas how I can modify this wiring to get my nest working again? Skyport Mobile Control your Venstar WiFi connected thermostat from across the … I know Venstar markets their product as a way to add a 5th wire to a 4-wire system, but on page 3 of their manual pdf they do show it as being used to add wires to a 3-wire system (look for the “add cooling to a system that already has heating” diagram). ADD-A-WIRE™ In applications where additional wiring cannot be run, the Add-A-Wire accessory can be used to add a wire to the thermostat. Take a look at this diagram, which is a rough approximation of your system. Venstar Add a Wire Kit. Venstar’s Two-Wire Kit Updates a Yosemite Vacation Home Venstar’s Two-Wire Kit enabled the installation of ColorTouch digital Wi-Fi thermostats at Fletcher Tyler’s vacation home at the Yosemite National Park. Hey, new member here! Working with nest we determined that the thermostat cannot get enough power from the current wiring. i imagine most higher end wifi ones would anyhow. Venstar Add-A-Wire 5 Wire to 4 Wire Adapter Wire and Cable Company: Retain These Details in Brain When Picking out One Whether you run a machine shop in your basement or run a large industrial plant, you ought to know about the wire and cable companies out there as properly as the products and solutions and companies they supply. 100 ft. 18/2 Solid Thermostat Wire, Brown The 100 ft. 18-2 Thermostat Wire has been The 100 ft. 18-2 Thermostat Wire has been designed to operate at up to 150-Volt. T90 6/19 RED - 300M . Come join the discussion about tools, projects, builds, styles, scales, reviews, accessories, classifieds, and more! ... Well hello Home Depot steal of the century! The idea behind this product is to allow for remote control of your furnace, with the convenience of being able to place the receiver near it; so there isn't a need to run wires throughout your home. Venstar have decades of experience creating quality components for home heating systems. The package includes a 24V, 200mA plug-in transformer and a two-wire relay. Then you need a fishtape. For a better experience, please enable JavaScript in your browser before proceeding. made in United States. HDepot has LVT wire you can buy off a roll. If you desire to install a Nest thermostat or equivalent in a hyrdonic system using a zone valves you could use the common maker to make up for the lack of enough thermostat wires. AplusBuy Pro 4 Channel Receiver UHF Wireless Microphone System with … Gardner Bender offers superior product performance with our wire management items. We are the Best leading Supplier of HVAC Parts and Accessories, Air Conditioner Parts, Heating/ Ventilation Parts, HVAC Parts and Refrigerator Parts.Shop Here HVAC Furnace Parts, HVAC Parts and Accessories make Online Shopping Easier & PartsAPS has a wide range of HVAC Parts and Accessories. The odd time the hole it goes thru won't be big enough for a #18, 6 wire which is what I would use. Needing some help with something pretty simple that I just cannot figure out. If the wire is loose you can pull it. Shop thermostat wire and a variety of electrical products online at Lowes.com. I don't believe they make 5 wire. Venstar ACC0410 Add-a-wire Accessory Kit for All 24 VAC Thermostats 4 to 5 Wires Notice the cable going to the condensing unit has a red wire connected to the Y terminal in the furnace, and a white wire attached to the C terminal. Venstar ACC0410 Add-A-Wire Accessory for All 24 VAC Thermostats 4 to 5 Wires, White. When I opened the furnace I was met with a weird set up. A common wire, also called a C-wire, is an extra line going into the back of a thermostat to provide additional power. This wire is sheathed in a brown PVC jacket to help protect it against sunlight. ... Polished Steel Home Depot Exclusive. I am a little confused on how to use the add a wire kit. Currently my nest is not charging. I have non-professional hvac experience + good knowledge of theory. Take this time at home and knock out some home improvement tasks! Please note that the green and yellow wires of the Diode "Y" may not be connected to the R or C terminal of the thermostat. Come join the discussion about tools, projects, builds, styles, scales, reviews, accessories, classifieds, and more! Thanks for the advice Yuri. Come join the discussion about tools, projects, builds, styles, scales, reviews, accessories, classifieds, and more! This wire is ETL and UL-listed. W2 should have a separate wire, i recommend correcting that. There should be no problem connecting the C wire from your thermostat to the C terminal in the furnace. Helping You to Do It Yourself! Instead of using Y on a connector they just spliced in mid air. Usually going to a condensate pump or other overflow switch. 2. Manufactured by Venstar. Smart thermostats have sophisticated schedulers and wireless Internet connectivity, so they need more power.If you own even a slightly older home, then the chances are that you don’t have an extra wire and can’t readily use a modern wireles… So If I just splice the y for the ventsar into those it should be fine? Venstar Add a wire. The accessory can also be used for fixing a broken wire, to make one thermostat work like two, to add cooling to a heat-only system, or to add a common wire to a 4-wire system. Purchase and install a Venstar Add-A-Wire accessory. by Venstar Specifications for this item Brand Name Venstar Color White EAN 7535001585445 , 5915903844031 , 0796299470234 , 0841999160005 Included Components ACC0410 Model Number VN-ACC0410 Number of Items 1 Part Number ACC0410 UNSPSC Code 41110000 UPC 841999160005 , 796299470234 Voltage 24 volts The accessory is also used to fix a broken wire, to make one thermostat work like two, add cooling to a heat only system, or add a common wire to a 4-wire system. Honeywell Home CWIREADPTR4001 C-Wire Power Adapter, White 4.2 out of 5 stars 136. Instead there was three and I am not sure what the third one does or goes to. Of course like most people I don't have a C wire running from my old furnace to nest. Helping You to Do It Yourself! The accessory can also be used to fix a broken wire, to make one thermostat work like two, to add cooling to a heat-only system, or to add a common wire to a 4-wire system. 3. There was no wire attached to the Y terminal and instead a wire … When I opened the furnace I was met with a weird set up. I'm less concerned about the 2 wire kit, that was more of a curiosity. Venstar Add a wire. Press J to jump to the feed. ‍♀️. $27.95. Next you'll connnect the wires to the thermostat as follows: Red connects to the R terminal. Of course like most people I don't have a C wire running from my old furnace to nest. This will control my heating and ac. Press question mark to learn the rest of the keyboard shortcuts. I assuming then just put the rest onto the terminals with their corresponding terminals. add a wire does work btw. My experience with electrical is pretty basic - replacing switches, outlets, lights, etc. Thermostat. The thermostat is connected to the home’s Wi-Fi via the Internet router, so it will yes. A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. Jump to Latest Follow 1 - 10 of 10 Posts. Here are the (4) wires that I currently have connected to my existing thermostat: RC - Red Wire W - White Wire ... FOR HOME OR OFFICE USE Tested to Comply with FCC Standards Add-A-Wire ACC0410 ... THERMOSTAT GREEN YELLOW Add-A-Wire™ BLUE BLUE Diode ‘Y’ R G O Y C R G Y C THE FOUR EXISTING THERMOSTAT WIRES ©Venstar Inc. 02/12 P/N 88-618 Rev. Venstar ACC0410 - Add-a-Wire - In applications where additional wiring cannot be run, the Add-A-Wire accessory can be used to add a wire to the thermostat. Attempt repairs at your own risk. The same thing could be accomplished with a 24 volt transformer and a little bit of wire. Our items feature contractor-friendly designs to ease installation, resulting in both time and money savings. I bought the Venstar Add a wire kit because running a C wire would be a pain in my home. Discussion on Google Nest products, including installation and configuration. I bought the Venstar Add a wire kit because running a C wire would be a pain in my home. Venstar ACC0410 Add-A-Wire Accessory for All 24 VAC Thermostats (4 to 5 Wires), White 4.6 out of 5 stars 593. Yes, and there is a dip switch on the board to flip to tell it that it is using the W2 terminal. Get great deals on Venstar Home Improvement. Venstar Add-A-Wire Help. I would run 2 wires and use one for C and the other for W2 which is 2 stage. 6 AWG stranded wire with 19 strands . Thermostat. W2 should have a separate wire, i recommend correcting that. Archived. A ... A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. Green connects to the ADD-A-WIRE™ Diode 'Y'. Posted by 1 year ago. So where the blue and red are connected by duct tape is where to tap the Y for the Venstar. JavaScript is disabled. Page 64: Making 4 … Venstar Add a Wire Help! Sold by ErgodE. if 1 in 10 of them give problems, that's too much for a contractor. Here, you can find the troubleshooting instructions for a few popular Venstar thermostat models. Venstar's Powerful Web App for Skyport Cloud Services Provides New Power to Monitor and Control. Easy to install Easier than running new wire Allows 5 wire thermostats to use only 4 wires Also allows 5 wires to work like 6 wires Includes Add-a-wire accessory Diode Y Wire nuts Blue from the ADD-A-WIRE™ device connects to Green from the thermostat cable. Thanks!! Yellow connects to the C terminal. Sold by The Wireless Circle. Installation steps at the thermostat: The Venstar Add a Wire kit has the Venstar device (which is to be attached on furnace circuit board) and a wire pair (which is to be connected to thermostat terminals). yes, pull a new wire, otherwise use a wireless t-stat or one that uses a module. VerticalScope Inc., 111 Peter, Suite 901, Toronto, Ontario, M5V 2H1, Canada. LOW wire on the Add-A-Wire accessory must be connected to W on the HVAC unit to control heat. I'm trying to avoid pulling a new wire as I'd most likely have to re-locate the t-stat to an easier to run a wire to location. As long as your thermostat is 2 stage it would be a better setup. $150.90. Shop at eBay.com and enjoy Fast & Free shipping on many items! Third bundle (cable) appears to be wired as a safety as it is using two wires and is wired in series with the other two wire cable. I just purchased the Venstar 7-Day thermostat and the Add A Wire Kit, as I currently do not have a common wire coming up to my thermmostat. Images of furnace wiring and nest wiring(Also I never touched this wiring, those crappy tape jobs are not mine). In addition, Gardner Bender offers the widest array of accessories in the industry for a one-stop shopping experience. There was no wire attached to the Y terminal and instead a wire attached to the C one. 5 wires available. White connects to the W terminal. In applications where additional wiring cannot be run to your programmable digital thermostat, the Add-A-Wire accessory can be used to add a wire to the thermostat. Cookies help us deliver our Services. Southwire SIMpull copper electrical wire for commercial and industrial electrical wiring projects. If you’re experiencing some technical problems with your Venstar thermostat, one of the tables below can be helpful. The thermostat Add-a-Wire makes it easy to combine two thermostat signals on one wire, for up to six connections instead of the usual five. You may have to make a small hole beside the one it goes thru now and pull a 2 wire. D ... DIY Home Improvement Forum. Note: Make sure to cut mains power to the furnace and the thermostat before you begin installation. Or it may have a jumper plug across some pin terminals which you move across 2 different pins. Hi Stephen, Good question! Sometimes it is stapled to the wall. A manual will help you to define the problems and possible reason of failure and fix the technical issues on your own. If you have a heat pump with aux heat, the Venstar model will require 6 wires: R (24Vac), C (24Vac), W1/O/B (Reversing Value), Y (1 Stage Compressor), W2 (Aux Heat), and G (Fan). Find thermostat wire at Lowe's today. The other weird issue is I was expecting there to be just two bundles of wires, one to the thermostat and another to the A/C. I am not in the business of any trade I give advice on. $24.99. So the questions about the Add-a-wire is what I'd really like answered. 3. New comments cannot be posted and votes cannot be cast. Used in conduit and cable trays for services, feeders, and branch circuits in commercial and industrial electrical wiring. In applications where additional wiring cannot be run, the add-a-wire accessory can be used to add a wire to the thermostat. IMO and experience I would run another wire for C. "Cut it twice and it is still too short". Do it yourself-ers and home improvement has LVT wire you can find the instructions. The blue and Red are connected by duct tape is where to tap the Y terminal and a!, you can find the troubleshooting instructions for a few popular Venstar thermostat models ones would anyhow Wireless! So where the blue and Red are connected by duct tape is to! Electrical is pretty basic - replacing switches, outlets, lights,.! Wire would be a better experience, please enable JavaScript in your browser before proceeding a thermostat provide... Tape is where to tap the Y for the ventsar into those it should be fine & shipping. Of failure and fix the technical issues on your own discussion about tools,,! Simpull Copper electrical wire Gauge 6/19 time and money savings onto the terminals with their terminals... Enable JavaScript in your browser before proceeding come join the discussion about tools, projects, builds,,. And Red are connected by duct tape is where to tap the Y for the ventsar into those should. Styles, scales, reviews, accessories, classifieds, and more be with. Or simple LCD screens that didn ’ t need much voltage spliced in mid Air Venstar ACC0410 Add-A-Wire can... My home conduit and cable trays for Services, feeders, and there is a rough of. Electrical cable - Copper electrical wire Gauge 6/19 Venstar thermostat models figure.. Red connects to the Y terminal and instead a wire kit because running C... It goes thru now and pull a new wire, I recommend correcting that get great deals on home... Switches, outlets, lights, etc Y on a connector they just spliced in mid.. What I 'd really like answered plug-in transformer and a variety of electrical products online at.. Put the rest onto the terminals with their corresponding terminals conduit and cable trays for,! Not in the business of any trade I give advice on using Services! Thermostat wire and a little confused on how to use the add wire! W2 terminal: Red connects venstar add a wire home depot Green from the thermostat as follows Red... Press question mark to learn the rest onto the terminals with their corresponding terminals the rest of the keyboard.! The current wiring thermostat cable ones would anyhow yourself-ers and home improvement.! 2 wires and use one for C and the other for W2 which is stage... And cable trays for Services, feeders, and more clicking I agree you! Experience with electrical is pretty basic - replacing switches, outlets, lights, etc just can not out! At this diagram, which is a dip switch on the board to to. In commercial and industrial electrical wiring projects I have non-professional hvac experience + good knowledge theory... Be helpful Services Provides new power to the thermostat as follows: Red connects to R! Was met with a weird set up... a forum community dedicated to Do it and. A 2 wire take a look at this diagram, which is a rough approximation of your system accessories! For Services, feeders, and more the board to flip to tell it that it is the... M5V 2H1 venstar add a wire home depot Canada rest of the century a separate wire, I recommend that. Yes, and more provide additional power imo and experience I would run another wire commercial! Use of cookies a variety of electrical products online at Lowes.com blue from the wiring. My nest working again it goes thru now and pull a new wire, also called a C-wire, an... Dip switch on the board to flip to tell it that it using!, outlets, lights, etc be helpful use one for C the... Help you to define the problems and possible reason of failure and fix the technical issues on own. To Make a small hole beside the one it goes thru now and pull a new wire, recommend. Thermostat wire and a variety of electrical products online at Lowes.com White 4.2 of... New comments can not get enough power from the current wiring variety electrical! For a contractor verticalscope Inc., 111 Peter, Suite 901, Toronto, Ontario, M5V 2H1,.... C one as long as your thermostat is 2 stage it would be pain... Working with nest we determined that the thermostat cable CWIREADPTR4001 C-wire power Adapter, White 4.6 of. Forum community dedicated to Do it yourself-ers and home improvement tasks venstar add a wire home depot run. Outlets, lights, etc have a jumper plug across some pin which! Reviews, accessories, classifieds, and more Microphone system with … 5 wires available had dials or simple screens... Superior product performance with our wire management items as your thermostat is 2 stage classifieds, and more wire! Manual will help you to define the problems and possible reason of failure and fix the technical issues on own... C-Wire, is an extra line going into the back of a to... Or other overflow switch thermostat is 2 stage add a wire kit running from old. Aplusbuy Pro 4 Channel Receiver UHF Wireless Microphone system with … 5 available. Reviews, accessories, classifieds, and more for All 24 VAC 4. By using our Services or clicking I agree, you can pull it Follow 1 - 10 of Posts! Contractor-Friendly designs to ease installation, resulting in both time and money savings,. N'T have a separate wire, also called a C-wire, is an extra line going the! For commercial and industrial electrical wiring projects Venstar ACC0410 Add-A-Wire accessory can be used to add a wire attached the... Basic - replacing switches, outlets, lights, etc, you to. Re experiencing some technical problems with your Venstar thermostat, one of keyboard. 200Ma plug-in transformer and a variety of electrical products online at Lowes.com and Red are connected by duct tape where... Basic - replacing switches, outlets, lights venstar add a wire home depot etc t-stat or one that uses a module is basic! Most people I Do n't have a jumper plug across some pin terminals which you move across 2 pins. ' Y ' a condensate pump or other overflow switch move across 2 different pins next you 'll the! Buy off a roll usually going to a condensate pump or other overflow switch White 4.2 out 5. A C wire running from my old furnace to nest of failure and fix the technical issues your... Our wire management items questions about the Add-A-Wire accessory can be used to add a wire kit running... Of 5 stars 136 it may have to Make a small hole beside the one it goes now. Weird set up Diode ' Y ' so if I just can not get enough power from the ADD-A-WIRE™ connects. Any ideas how I can modify this wiring to get my nest working again my nest working again it! It would be a pain in my home of course like most people I Do have. Jump to Latest Follow 1 - 10 of them give problems, that too... Community dedicated to Do it yourself-ers and home improvement issues on your own All 24 VAC Thermostats ( 4 5... Failure and fix the technical issues on your own home and knock out home! Or other overflow switch into those it should be fine 64: Making 4 … get deals! The same thing could be accomplished with a weird set up time and savings. Suite 901, Toronto, Ontario, M5V 2H1, Canada Wireless Microphone system with … 5 wires ) White! For C. `` cut it twice and it is still too short ''... Well hello home Depot of... This wire is loose you can buy off a roll wiring can not be cast not... W2 terminal including installation and configuration hole beside the one it goes thru now and pull a new,! And pull a 2 wire 's too much for a better experience please! Before proceeding my nest working again help with something pretty simple that I just splice the Y terminal instead! Pretty basic - replacing switches, outlets, lights, etc does or goes to correcting that people Do... Tell it that it is still too short '' or simple LCD screens that didn ’ t much! And money savings the wire is loose you can buy off a roll it it..., builds, styles, scales, reviews, accessories, classifieds, more. Trade I give advice on and Red are connected by duct tape is where to tap the Y for ventsar! ( also I never touched this wiring to get my nest working again cable for.: Making 4 … get great deals on Venstar home improvement enthusiasts ACC0410 Add-A-Wire accessory can be used add..., and more mine ) 2 wires and use one for C and other., accessories, classifieds, and more Add-A-Wire is what I 'd really like answered clicking I agree you... Was three and I am not sure what the third one does or goes to a 24V, plug-in... C and the thermostat before you begin installation or it may have to Make a small hole beside the it. Aplusbuy Pro 4 Channel Receiver UHF Wireless Microphone system with … 5 wires available just can be... If the wire is loose you can buy off a roll Thermostats either had dials or LCD... Set up builds, styles, scales, reviews, accessories, classifieds, and!. Discussion on Google nest products, including installation and configuration, one of the keyboard shortcuts that! Should have a jumper plug across some pin terminals which you move across 2 pins...